Home > Products > Products & Solutions > Products > Data Center (IDC Micro module)

Data Center

Channel system controls the air transport path, provides high density of refrigeration guarantee;

  • Product Description

  • Product Features

  • Structure Selection

Micro-module Data Center Air Cooling Aisle System                 

                                                                 

Data center - Cold channel closed system.jpg

    Data center - Cold channel closed system.jpg


Low density cold aisle system (UPS external)




Data center - Cold channel closed system.jpg

High density cooling aisle system (UPS built-in)



Product standards:

Comply with ANSI/EIA RS-310-D, IEC297-2, DIN41491; PART1, DIN41494; Part7, GB/ T30472-92 standard, compatible with 19-inch international standard, metric standard and ETSI standard.


Product Characteristics

1. The surface adopts degreasing, ceramic, electrostatic spraying process, in line with the European ROHS environmental protection standard;

2. The sliding door adopts double-layer composite door body design of cold-rolled steel to ensure the strength of the door;

3. The middle part of the sliding door adopts transparent toughened glass design, which is easy to view the internal situation of the cold pool channel from the outside;

4. The cold channel adopts a 10-inch monitoring screen, with good man-machine interface and touch control performance, which can monitor the internal environment of the cold channel, such as electricity, temperature and humidity, smoke, video, water leakage, etc.


Main materials:

      All made of high quality cold-rolled steel plate, Angle gauge 2.0mm, frame 1.5mm, other 1.2mm.


Application scenarios:

Mainly used in communication, finance, securities, data center and other computer rooms, such as bank outlets, municipal government agencies, small and medium-sized enterprise computer rooms, education, medical and other small and medium-sized data center scene. It can also be applied to large data centers through centralized deployment, such as public cloud data centers, IDC data centers, etc.

Data center - Cold channel closed system.jpg



Jiancheng also provide UPS Power, Industrial Control CabinetSubrack, etc.    


                                                                                    Reliable                                                                           

1. The key components of the system adopt N+1 or 2N design to ensure the stable operation of the equipment to the maximum extent;

2. The internal circuit breaker of the precision distribution cabinet adopts Schneider, ABB or other well-known brands of the same level;

3. Support the intelligent linkage between skylight and fire, automatically open the skylight 0.5 seconds after receiving the fire signal to let the fire extinguishing gas enter;

4. UPS ultra-wide voltage and frequency input range, compatible with all kinds of oil-fired generators.

 

                                                                         High Efficiency                                                                          

1. High efficiency modular UPS, the efficiency of the whole machine is more than 95%;

2. Closed cold and hot channel isolation design, avoid gas mixed flow, ensure refrigeration efficiency;

3. Proximal row cooling reduces the loss of cold volume, and the overall PUE of the micro module is reduced to less than 1.5


                                                                         Intelligent                                                                                  

1. UPS supports intelligent sleep function, which automatically calls corresponding power modules according to the load;

2. Row level air conditioning adopts frequency conversion compressor and EC fan, which can automatically adjust the air output;

3. Support local alarm, SMS alarm, web alarm, WeChat alarm, etc.;

4. The translation door standard at both ends of the airtight cold channel is equipped with anti-clamp function


                                                                         Convenient                                                                                

1. Standard components, module architecture, plug-and-plug maintenance;

2. No need for professional machine room, can be directly placed on the concrete floor of the building, reduce the external supporting works;

3.  Convenient capacity expansion, fast deployment on demand for matching business;

4.  Unified monitoring and management, remote operation and maintenance, simply and easily


Structure Selection

Automatic double sliding door (Fingerprint access control)

 Manual double push-pull door.jpg

Structural feature

Located at the end of the data center;

The thickness of the main sheet metal structure material is not less than 1.2mm, and the width of the cooling channel is 1200mm;

12mm toughened glass automatic door; IC card; fingerprint; password access control; electric guide rail and safety dual beam,

Door box assembly with cooling channel closed sliding door.

 

Materials & Surface treatment

RAL9005 matte fine sand pattern, coated with plastic powder on the surface of cold rolled steel plate

Product Name

Product Properties

10Automatic double-opening sliding doors

Applicable to 1000   depth 2000MM cabinet double row cooling channel

12Automatic double-opening sliding doors

Applicable to 1000   depth 2000MM cabinet double row cooling channel



Manual double opening sliding door

 

Manual double push-pull door.jpg


Structural feature

Located at the end of the data center;

The thickness of the main sheet metal structure material is not less than 1.2mm, and the width of the cooling channel is 1200mm;

12mm toughened glass automatic door; door handle;

Door box assembly with cooling channel closed sliding door.

 

Materials & Surface treatment

RAL9005 matte fine sand pattern, coated with plastic powder on the surface of cold rolled steel plate

Product Name

Product Properties

10 Manual double   opening sliding doors

Applicable to 1000   depth 2000MM cabinet double row cooling channel

12 Manual double   opening sliding doors

Applicable to 1200   depth 2000MM cabinet double row cooling channel



Manual double push-pull door

 Manual double push-pull door.jpg

Structural feature

Located at the end of the data center;

The thickness of the main sheet metal structure material is not less than 1.2mm, and the width of the cooling channel is 1200mm;

5MM tempered glass perspective window; Manual push-pull door; door handle;

Built-in hidden automatic door closers; Reserved the position of skylight control switch;

 

Materials & Surface treatment

RAL9005 matte fine sand pattern, coated with plastic powder on the surface of cold rolled steel plate

Product Name

Product Properties

10 Manual double push-pull doors

Applicable to 1000   depth 2000MM cabinet double row cooling channel

12 Manual double push-pull doors

Applicable to 1200   depth 2000MM cabinet double row cooling channel


_ueditor_page_break_tag_

Linear Skylight

Manual double push-pull door.jpg

 

Structural feature

Located at the head and tail of the cooling channel column; Right Angle.

Half of the width is fixed glass skylight (stick explosion-proof film), the other half is metal trough, used for the line between the column and the installation of monitoring equipment;

Equipped with a LED human body sensor light, support plate of height 300MM.

 

Materials & Surface treatment

RAL9005 matte fine sand pattern, coated with plastic powder on the surface of cold rolled steel plate

Product Name

Product Properties

600 Linear   Skylight

Applicable to 600   width (300mm wire trough, 300mm fixed glass)

800 Linear   Skylight

Applicable to 800   width (300mm wire trough, 500mm fixed glass)

 


Fixed Skylight

Manual double push-pull door.jpg

Structural feature

Located at the center of the cooling channel; Right Angle.

Width 300mm, 600mm for fixed glass skylight (with explosion-proof film), 800mm width of which half 300mm wide is glass skylight, the other half 500mm is steel skylight, used for the installation of monitoring equipment;

Equipped with a LED human body sensor light, support plate of height 300MM.

 

Materials & Surface treatment

RAL9005 matte fine sand pattern, coated with plastic powder on the surface of cold rolled steel plate

Product Name

Product Properties

300 glass fixed   skylight

Applicable to cabinet   width of 300, cooling channel width of 1200

600 glass fixed   skylight

Applicable to cabinet   width of 600, cooling channel width of 1200

1200 glass fixed   skylight

Applicable to cabinet   width of 800, cooling channel width of 1200



Single-open flipping skylight

Manual double push-pull door.jpg

Structural feature

Located at the center of the cooling channel; Right Angle. (with explosion-proof film),

With 12V magnetic lock

Equipped with a LED human body sensor light, support plate of height 300MM.

 

Materials & Surface treatment

RAL9005 matte fine sand pattern, coated with plastic powder on the surface of cold rolled steel plate

Product Name

Product Properties

600 single-open   flipping skylight

Applicable to cabinet   width of 600, cooling channel width of 1200

 


Double-open flipping skylight

 

Manual double push-pull door.jpg


Structural feature

Located at the center of the cooling channel; Right Angle. (with explosion-proof film),

With 12V magnetic lock

Equipped with a LED human body sensor light, support plate of height 300MM.

 

Materials & Surface treatment

RAL9005 matte fine sand pattern, coated with plastic powder on the surface of cold rolled steel plate

Product Name

Product Properties

600 double-open   flipping skylight

Applicable to cabinet   width of 600, cooling channel width of 1200

800 double-open   flipping skylight

Applicable to cabinet   width of 800, cooling channel width of 1200


_ueditor_page_break_tag_

Cable slot at the top of cabinet

 

Cable slot at the top of cabinet.jpg


Structural feature

Adopt clamp type structure, and can realize the isolation of different cables (such as network cable, optical fiber), to ensure the independence of various cabinets or air conditioners, the cable slots over the cable wire are equipped with wire protection teeth.

 

Materials & Surface treatment

Cold rolled steel 1.5mm, surface spray treatment.

Product Name

Product Properties

M shape Cable slot   300mm

Applicable to cabinet   width of 300

M shape Cable slot   600mm

Applicable to cabinet   width of 600

M shape Cable slot   800mm

Applicable to cabinet   width of 800

 

_ueditor_page_break_tag_

Electric Distribution collections box

 

Electric Distribution collections box.jpg


Structural feature

Including 12V switching power supply (320W), 12-bit terminal bar, to the magnetic lock and LED lighting power supply, reserved fire signal dry contact.

Must require;

According to the cold channel configuration to determine whether the power supply is enough, if not enough, need to customize the high-power supply.